Compressed Air Leakage Cost Calculation

Air leakage flow rate according to hole diameter and pressure, lost power and annual cost.

Compressed air is one of the most expensive forms of energy in factories, and 20–30% of the air produced in a typical plant is lost to leaks. This tool calculates the flow rate of a leak of a certain diameter, the power wasted in the compressor, and the annual cost .

Formula (critical flow)

ṁ = C · A · p₀ · √(κ / (R · T₀)) · (2 / (κ + 1))^((κ+1) / (2(κ−1)))

κ = 1.4, R = 287 J/(kg· K). The flow rate is given as free air (FAD, 1.013 bar, 20 °C). With C = 1, the results are the same as the U.S. Department of Energy (DOE) leak tables; for true holes with sharp edges, C ≈ 0.61–0.65 can be entered.

Example

In a 7 bar(g) line, a 3 mm leak approximately 11.1 L/s of free air and wastes 4.3 kW of power in the compressor. In 8,000 hours per year, this amounts to 34,600 kWh, or approximately 139,000 ₺ with 4 ₺/kWh of electricity. The annual cost of even a 1 mm leak exceeds 15,000 ₺.