Skip to content
Boilers and Energy

Boiler Efficiency Calculation

Steam boiler efficiency and load factor from feed water and fuel consumption.

Boiler efficiency shows how much of the energy given by fuel is transferred to steam. This tool calculates efficiency by direct (input-output) method: simply select the fuel type and enter the measured feed water (or steam) flow rate and fuel consumption.

Formula

η = [steam × (hf +

Hu is the lower calorific value of the fuel (kcal/Sm³, kcal/kg or kcal/L; the typical value comes when you select the fuel), x is the steam dryness fraction (default 98%). hf and hfg are calculated at boiler pressure, hfw at feed water temperature, with IAPWS-IF97. If you are using a feed water meter, steam flow = feed water − blowdown; the heat discharged with blowdown is counted as useful output according to EN 12953-11 and ASME PTC 4, and the value that counts blowdown as a loss is also shown separately.

Example

If 1,000 kg/h feed water and 76 Sm³/h gas consumption are measured with 80 °C feed water in a boiler burning natural gas (Hu = 8,250 kcal/Sm³) and operating at 10 bar(g) pressure, the useful heat is 668.3 kW, the fuel heat is 729.2 kW and the boiler efficiency is 91.64%; at a rated capacity of 2,000 kg/h, the load factor is 50% (13.16 kg steam with 1 Sm³ gas).

Çiftel Kazan’s boilers operate with thermal efficiency between 85-95% depending on type, fuel and operating conditions. For steam boiler selection, you can take a look at our steam boiler guide and get free quote for your project.

FAQ

Frequently Asked Questions

Chat on WhatsApp Get a Quote